Negotiable
The date of payment from buyers deliver within days
Zhejiang
Long-term effective
2018-08-26 03:45
262
Company Profile
Yueqing Aukeman Trading Co.,LtdBy certification [File Integrity]
Contact:aukeman(Mr.)
Email:
Telephone:
Phone:
Area:Zhejiang
Address:Zhejiang
Website:http://www.cnakm.net/ http://aukeman.greenerworldproduct.com/
Applications
Used in air conditioning units, elevator machine room, pumps, fans and other motor control applications, as protection of over-voltage. Uunder voltage, phase failure, phase sequence, phase imbalance and PTC temperature. When the power supply is abnormal, turn off power supply to protect the equipment.
Features:
Built-in microprocessor, true RMS measurement, measurement accuracy≤1%. 50/64Hz universal, knob setting, LED indicator shows working status. Withe N-phase phase failure protection, unique load-side and PTC temperature protection, optional manual reset and key test function, DIN rail mounting.
Model Description
Model Selection Table
Model |
Over-voltage |
Under-voltage |
Unbalance |
Phase sequence |
Phase failure |
Reset |
Test |
PTC Protection |
Load protection |
|||
ZHRV1 |
Setting range |
Delay range |
Setting range |
Delay range |
Setting range |
Delay range |
||||||
01 |
1.05...1.30 |
0.1s...10s |
- |
- |
- |
- |
- |
+ |
- |
- |
- |
- |
02 |
- |
- |
0.70...0.95 |
0.1s...10s |
- |
- |
- |
+ |
- |
- |
- |
- |
03 |
1.05...1.30 |
0.1s...10s |
0.70...0.95 |
0.1s...10s |
- |
- |
- |
+ |
- |
- |
○ |
○ |
04 |
1.05...1.30 |
0.1s...10s |
0.70...0.95 |
0.1s...10s |
- |
- |
+ |
+ |
- |
- |
○ |
○ |
05 |
1.05...1.30 |
0.1s...10s |
0.70...0.95 |
0.1s...10s |
8% |
2s |
- |
+ |
- |
- |
○ |
○ |
06 |
1.05...1.30 |
0.1s...10s |
0.70...0.95 |
0.1s...10s |
8% |
2s |
+ |
+ |
- |
- |
○ |
○ |
07 |
1.05...1.30 |
0.1s...10s |
0.70...0.95 |
0.1s...10s |
5%...15% |
0.1s...10s |
- |
+ |
- |
- |
○ |
○ |
08 |
1.05...1.30 |
0.1s...10s |
0.70...0.95 |
0.1s...10s |
5%...15% |
0.1s...10s |
+ |
+ |
- |
- |
○ |
○ |
09 |
1.05...1.30 |
2s |
0.70...0.95 |
2s |
8% |
2s |
- |
+ |
- |
- |
○ |
○ |
10 |
1.05...1.30 |
2s |
0.70...0.95 |
2s |
8% |
2s |
+ |
+ |
○ |
○ |
○ |
○ |
11 |
1.15 |
2s |
0.85 |
2s |
5%...15% |
0.1s...10s |
- |
+ |
○ |
○ |
○ |
○ |
12 |
1.15 |
2s |
0.85 |
2s |
5%...15% |
0.1s...10s |
+ |
+ |
○ |
○ |
○ |
○ |
13 |
1.15 |
2s |
0.85 |
2s |
8% |
2s |
- |
+ |
○ |
○ |
○ |
○ |
14 |
1.15 |
2s |
0.85 |
2s |
8% |
2s |
+ |
+ |
○ |
○ |
○ |
○ |
15 |
1.15 |
2s |
0.85 |
2s |
- |
- |
- |
+ |
○ |
○ |
○ |
○ |
16 |
1.15 |
2s |
0.85 |
2s |
- |
- |
+ |
+ |
- |
- |
- |
- |
17 |
- |
- |
- |
- |
5%...15% |
0.1s...10s |
+ |
+ |
- |
- |
- |
- |
18 |
- |
- |
- |
- |
- |
- |
+ |
+ |
- |
- |
- |
- |
19 |
- |
- |
- |
- |
8% |
2s |
+ |
+ |
- |
- |
- |
- |
Note:
1. "+"Function is available, "-"Function is not availble. "○"Function can be customized.
2. In three-phase four-wire circuit, relay without phase sequence protection could acheive sigle-phase or two-phase protection.
3. Choose either PTC protection or load protection.
4. Load protection: L1/L2/L3(P-P).
Technical Parameters
Rated supply voltage |
AC220V、AC230、AC240V、AC380V、AC400V、AC415V |
Rated supply frequency |
50Hz/60Hz |
Over-voltage threshold range |
(1.05~1030) ×Ue |
Under-voltage threshold range |
(0.70~0.95) ×Ue |
Unbalance threshold range |
5%~15% |
Action delay range |
0.1s~10s |
Phase failure and phase sequence |
≤1s |
Voltage measurement error |
≤1%(Entire setting range) |
Delay error |
±10%+0.1s |
Knob setting accuracy |
±1% Scale value |
Rated insulation voltage |
415V |
Contact configuration capacity(A) |
10A |
IP Class |
IP20 |
Class of pollution |
3 |
Electrical Life |
105 |
Mechanical life |
106 |
Altitude |
≤2000m |
Allowable relative humidity |
≤50%(40℃)(No condensation) |
Use category |
AC-15 |
Short circuit protector type |
RT36-00 5A |
Contact capacity |
Ue/le:240V/1.5A,415V/0.95A |
Output type |
1C/O |
DIN rail Standard |
(width)35mm (IEC/EN60715) |
Function diagram
Wiring Diagram
Dimensions(mm)
Model significance:
ZHRV1-04/A380 voltage relays, rated coltage AC 380V with phase failure, phase sequence, over-voltage protection. Adjustable over-voltage range(1.05-1.3)Ue, under-voltage range(0.7-0.95)Ue, unbalance protection range(5%-15%)Ue, action delay time 0.1s to 10s.
http://www.cnakm.net/